Detailed Parameter Table
| Parameter name | Parameter value |
|---|---|
| Product model | P11-314DR |
| Manufacturer | CTC / Parker Automation |
| Product category | Operator interface / HMI “PowerStation” (P1 series) |
| Display type & size | STN (color), 5.7-inch diagonal |
| Display resolution & colors | 320 × 240 pixels (¼ VGA), 256 colors |
| Memory / storage | Base 4 MB solid state flash (expandable via internal FLASH disk) |
| Communication / I/O interfaces | RS-232 / RS-422 / RS-485 (shared port), second RS-232 port; NE2000 Ethernet 10 Mbps (10Base-T) |
| Power supply | 18 to 30 V DC, nominal 24 V DC; typical power consumption up to ~50 W |
| Physical size / weight | Approx. 7.8″ × 5.6″ × 3.2″ (L × W × D); weight ~2.5 lb |
| Operating temperature | (typical industrial rating) ~0 °C to +50 °C (check specific variant) |
| Storage temperature / humidity | –20 °C to +60 °C (non-condensing humidity) |
Product Introduction
The P11-314DR is a color operator interface module from CTC’s P1 PowerStation family (under Parker/CTC Automation). As a fully integrated HMI “PowerStation”, P11-314DR combines operator display, serial communications, and control logic capabilities in one robust industrial module. The “DR” suffix denotes a color STN (Super-Twisted Nematic) display variant, differentiating it from monochrome versions in the same family.
In deployment, P11-314DR commonly operates as an intelligent front-end in automation systems: it provides users with dynamic visual feedback, touch or key-based parameter interaction, alarm monitoring, trend display, and higher-level network connectivity. It also supports communications via RS-232/485 and a built-in Ethernet interface (NE2000), enabling it to function as a gateway or network bridge among devices. The module’s flexible architecture accommodates expansion of memory, firmware upgrades, and adaptation to varied control network topologies.
Within a control architecture, P11-314DR often acts as the human-machine bridge—displaying process data, accepting setpoint or control commands from operators, and relaying information upstream to controllers or SCADA. Its built-in resources relieve upstream controllers of basic HMI tasks. Its modular design and support for field upgrades make P11-314DR a long-life choice in industrial, process, machine control, and retrofit applications.
Core Advantages and Technical Highlights
Process-centric HMI with color display:
With its color STN display and 320×240 resolution, P11-314DR offers richer graphics than monochrome counterparts. The color capability enhances readability of status, alarm differentiation, and trend visualization. It can display icons, scaled indicators, alarm banners, and operator menus with heightened clarity.
Integrated communication flexibility:
P11-314DR supports multiple serial protocols (RS-232, RS-422, RS-485) on its primary I/O port and a secondary RS-232 port. Moreover, it supports NE2000-compatible Ethernet (10 Mbps, RJ45) for TCP/IP or field network integration. This mix provides flexibility in networking to controllers, PLCs, or SCADA systems.
Expandable storage and firmware adaptability:
While it comes with a base 4 MB flash memory, the module supports internal FLASH disk expansion for data logs, recipe sets, or backup functions. Firmware upgrades can be loaded to enhance features or fix bugs, ensuring long-term viability in evolving system environments.
Industrial robustness and modularity:
The P11-314DR is housed in a solid enclosure suitable for panel mounting or industrial installation. Internal circuitry is designed to withstand field stresses. Modular architecture allows replacement of internal storage, display, or logic boards if required, reducing full-module replacement costs.
Ease of deployment and retrofit readiness:
Because P11-314DR is part of the P1 PowerStation series, it shares form factor and interface standards with sibling models. This compatibility simplifies substitutions or upgrades in legacy systems. The unit’s built-in communication ports and memory capacity reduce the need for separate gateways or external modules.
Diagnostic and continuity resilience:
Embedded diagnostics monitor communication errors, display health, memory integrity, and system activity. In case of partial failure (e.g., display fault), P11-314DR can still act as a network interface or pass-through device, preserving operations until full repair.
Altogether, P11-314DR distinguishes itself by combining color display, multiple communication interfaces, upgradeable memory, and rugged field design into a single operator station unit, making it a valuable component in modern industrial automation and retrofits.
Typical Application Scenarios
P11-314DR is often applied in industrial environments where a compact yet capable operator interface is needed, particularly when retrofitting older systems or integrating modular control stations. Typical use cases include:
-
Process industries: P11-314DR can sit at the input side of pumps, chemical dosing skids, or mixing units, displaying loop variables, alarm status, trends, and letting operators adjust setpoints or modes.
-
Machine control systems: In production machinery, P11-314DR provides menus, diagnostics, counts, and fault messages directly at the machine, reducing the need for additional control panels.
-
Retrofit projects: When updating older panel systems, P11-314DR may replace legacy monochrome HMIs, leveraging its compatibility in mounting and communication to minimize wiring changes.
-
SCADA front-end: P11-314DR can act as a local bridge or gateway in remote sites, connecting field devices to Ethernet networks while presenting operator screens for on-site control or Diagnostics.
-
Utility and infrastructure: In pump stations, water treatment, HVAC control rooms, P11-314DR serves as the local supervisory interface, showing flows, levels, alarms, and enabling control override or mode selection.
In such contexts, P11-314DR adds value by reducing cabling complexity, offering local operator capability, and supporting color visualization for clearer user interaction. Its network ports allow it to seamlessly integrate into DCS, PLC, or SCADA architectures.
Related Model Recommendations
-
P11-014DR – Monochrome (non-color) version of the P1 PowerStation in the same family, with otherwise similar interfaces; useful when color display is unnecessary.
-
P11-314 (non-DR variant) – Possibly an earlier or more basic color version; compatible in form factor but lacking the “DR” enhancements.
-
P1H series – High-performance or compact versions of the P1 PowerStation family; ideal for more demanding display or processing needs.
-
P11-314DD – A variant with differential display or double-display layout; useful when dual screens or mirrored panels are needed.
-
P1-014 – Base unit in the P1 family, often sharing backplane or I/O interface standards with P11-314DR.
-
P11-214CR – Another color variant in the same generation; offers alternate screen size or enhanced memory capacity.
-
P11-314ER – Enhanced version with extra memory or Ethernet options; serves as an upgrade path from P11-314DR.
-
P1 PowerStation family modules – All share mounting and communication conventions, so modules can often be swapped or replaced among variants with minimal rewiring.
Each recommended model is closely aligned in the P1 PowerStation family and offers either variant features, display modes, or upgrade paths that complement or replace P11-314DR in different applications.
Installation, Commissioning and Maintenance Instructions
Installation preparation:
Ensure the panel cutout matches the required dimensions and that the surrounding environment meets ingress, temperature, and vibration standards. Confirm the power supply is stable and within 18–30 V DC, properly fused. Use shielded cabling for RS-232/485, Ethernet, and ground shields at one end only to avoid ground loops. ESD precautions should be observed when handling internal modules or display boards.
Commissioning:
Mount P11-314DR, apply power, and observe the boot sequence. Verify the display is functional and that network ports are responding (serial echo, Ethernet link status). Load configuration or application files via RS-232 or Ethernet, then test communication to field devices or controllers. Validate display screens, alarm lists, menus, trends, and operator input paths. Check memory expansion recognition if additional FLASH modules are installed. Finally, simulate fault conditions to ensure diagnostic behavior is correct.
Maintenance suggestions:
Periodically inspect keypad or touch front surface (if applicable) for wear or contamination. Clean the screen and enclosure with non-abrasive, non-conductive materials. Monitor internal diagnostics for memory errors, communication faults, or display anomalies. Backup all configuration and application data to external repository regularly. For modules with expandable memory, check periodically whether the FLASH disks are healthy. If display or communication faults occur, isolate the fault (display vs logic vs I/O) and replace the appropriate internal module. Avoid field-level PCB repair unless qualified; instead, replace with service-certified modules.
Service and Guarantee Commitment
CTC / Parker Automation offers full factory testing and calibration of every P11-314DR before shipment, ensuring performance reliability and interface integrity. A standard warranty is provided covering manufacturing defects in materials and workmanship within an agreed period from delivery.
Should you experience any hardware or firmware issue, authorized repair services are available, offering component-level diagnostics, module replacement, and firmware restoration. Repaired units are subjected to full functional tests to match factory benchmarks before return to service.
Our technical support team is prepared to assist with programming, network integration, display design, troubleshooting, and migration planning. Spare parts such as display modules, memory boards, and interface cards are held in inventory to reduce downtime. With our dedication to quality assurance and customer service, your investment in P11-314DR is secured with professional support and reliability assurance.