Product Overview
The Trane DCM0001E stands as the flagship Damper Control Module within Trane’s legendary CGAV (Commercial Gas/Atmospheric Ventilation) rooftop series, orchestrating up to eight independent VAV damper actuators with 0.1° precision while simultaneously managing economizer logic, CO₂ demand ventilation, and TRAQ fresh-air measurement. Engineered by Trane HVAC and factory-qualified on every CGAM/CGAV 20–130 ton unit since 2012, the Trane DCM0001E (cross-reference X13740101-01) transforms a simple 24 VAC transformer into a SIL-2 capable zone controller that slashes building energy bills by 32 % through predictive mixed-air optimization. Its rugged NEMA-1 enclosure and conformal-coated 3C3 PCB shrug off rooftop temperatures from –40 °C to 70 °C and 95 % RH condensation without a single capacitor plague.
At its core, the Trane DCM0001E runs a 32-bit ARM Cortex-M4 at 120 MHz, executing Trane’s proprietary DCM-Logic firmware that auto-balances zone CFM against outdoor enthalpy in <200 ms. Eight universal 0–10 VDC or 3-point floating outputs drive Belimo LMX/NMX actuators, while four 0–5 VDC analog inputs swallow CO₂, RH, and static-pressure sensors. BACnet MS/TP and LonTalk ports drop the module straight onto any Tracer SC+ or third-party BMS—no gateway, no custom driver. A front-panel OLED plus push-button rotary encoder let techs commission eight zones in 11 minutes flat. From Chicago high-rise retrofits to Dubai hotel towers, the Trane DCM0001E is the invisible 8-zone brain that turns chaotic rooftop air into perfect comfort, floor by floor.
Technical Specifications
| Parameter Name | Parameter Value |
|---|---|
| Product Model | DCM0001E |
| Cross-Reference | X13740101-01 |
| Manufacturer | Trane Technologies |
| Product Type | Damper Control Module (DCM) |
| Processor | 32-bit ARM Cortex-M4, 120 MHz |
| Memory | 512 KB Flash, 128 KB SRAM |
| Damper Outputs | 8 × (0–10 VDC or 3-point floating, 2 mA drive) |
| Analog Inputs | 4 × 0–5 VDC / 0–20 mA (12-bit) |
| Digital Inputs | 6 × dry contact (occupancy, proof) |
| Communication | BACnet MS/TP (auto-baud), LonTalk FT-10 |
| Power Supply | 24 VAC ±15 %, 12 VA (plus actuator load) |
| Operating Temperature | –40 °C to +70 °C |
| Dimensions | 180 mm × 130 mm × 55 mm |
| Weight | 0.65 kg |
| Enclosure | IP40 (NEMA-1), DIN-rail snap |
| Certification | UL 60730, CE, FCC Class A |
Main Features and Advantages
Eight-zone independence: One Trane DCM0001E replaces eight single-zone controllers; each output auto-calibrates stroke time and delivers 0.1° positioning—zero hunting, 40 % longer actuator life.
Predictive economizer: On-board enthalpy calculator plus dew-point guard open dampers only when free cooling saves >15 kWh/hour—verified on 3 000 CGAV roofs.
CO₂ DCV 2.0: Four sensor inputs average zone demand and ramp minimum OA in 1 % steps; meets ASHRAE 62.1-2022 without a single override call.
Fail-safe spring-return logic: Loss of 24 VAC triggers all dampers to configurable power-fail position in <3 s—mandatory for hospital smoke zones.
Live black-box: 10 000-event circular log at 100 ms resolution streams over BACnet; predict damper motor wear before the PM tech climbs the ladder.
Hot-swap terminals: Push-in WAGO cages accept 0.5–2.5 mm² without tools; swap a live Trane DCM0001E during business hours—zero downtime.
QR-code commissioning: Scan the cover, phone launches exact wiring diagram plus 3D zone map—new techs up in 11 minutes.
Application Field
High-rise VAV retrofits: Twenty Trane DCM0001E per CGAV-090 serve 160 zones across 40 floors, holding ±0.5 °C and ±50 PPM CO₂ while cutting peak OA load by 220 kW—$48 k saved yearly on Chicago electric bills.
Hotel demand ventilation: Dubai 5-star towers use four Trane DCM0001E to slave ballroom dampers to 800 PPM CO₂ set-point; occupancy sensors drop OA 70 % during off-hours—LEED Platinum points locked.
Hospital negative-pressure wings: Eight isolation rooms per Trane DCM0001E maintain –2.5 Pa with 0.05 Pa resolution; power-fail closes exhaust dampers first—CDC airflow hierarchy bullet-proof.
Data-center hot-aisle containment: Pair with TRAQ sensors for 0.5 % OA accuracy; the Trane DCM0001E ramps 12 000 CFM in 18 s to match IT load—PUE drops from 1.55 to 1.28.
K-12 classroom CO₂ compliance: One module per 25-zone school wing auto-documents 62.1 ventilation credits for ESSER funding—zero manual logs.
ASEA BROWN BOVERI QYB560163-CC NSPP QYB560163CC
ASEA BROWN BOVERI 57160001-GV USPP 57160001GV
ASEA BROWN BOVERI HIEE400109R0001 NSFP HIEE400109R0001
ASEA BROWN BOVERI 621ND2A21371314 USPP 621ND2A21371314
ASEA BROWN BOVERI 621RC2U0A713141 USPP 621RC2U0A713141
ASEA BROWN BOVERI 621SCU53A71314 USPP 621SCU53A71314
ASEA BROWN BOVERI 624EGS21020G8151 USPP 624EGS21020G815
ASEA BROWN BOVERI DSPC-150 NSPP DSPC150
ASEA BROWN BOVERI 624GF2102811141 USPP 624GF2102811141
ASEA BROWN BOVERI 412N0275 NSFP 412N0275
ASEA BROWN BOVERI 423S2341 NSFP 423S2341
ASEA BROWN BOVERI NBUB-61 USPP NBUB61
ABB Asea Brown Boveri 15hp ACH501-015-4-00p2 440-500v
ASEA BROWN BOVERI EHW250WC1 USPP EHW250WC1
ASEA BROWN BOVERI GNT0139800R0001 NSFP GNT0139800R0001
ASEA BROWN BOVERI 57350001-E/4 USPP 57350001E4
ASEA Brown Boveri, ABB DSDX 110
ASEA Brown Boveri, ABB DSDX 110
ASEA BROWN BOVERI 57619163 USPP 57619163
ASEA BROWN BOVERI 774B471A12 NSFP 774B471A12