Detailed Parameter Table
| Parameter Name | Parameter Value |
|---|---|
| Product Model | DE41F |
| Manufacturer | ABB |
| Product Category | Compact Electromagnetic Flowmeter Primary |
| Nominal Diameter Range | DN 10 … DN 200 (3/8″ … 8″) |
| Pressure Rating | PN 16 / PN 40 / ASME CL150 / CL300 |
| Liner Material | Hard rubber or PFA (vacuum-proof) |
| Electrode Material | Hastelloy C, Tantalum, Platinum |
| Accuracy | ±0.4 % of rate (standard) |
| Process Temperature | –10 °C … +130 °C (hard rubber) |
| Ambient Temperature | –20 °C … +60 °C |
| Protection Class | IP 67 (standard) / IP 68 (remote) |
| Supply Voltage | 100 … 230 V AC ±10 % or 24 V DC |
| Outputs | 4-20 mA HART, Pulse, Status |
| Installation Method | Flanged DIN / ANSI, horizontal or vertical |
Product Introduction
The ABB DE41F is the legendary compact electromagnetic flowmeter primary that turned every brown-field pipe into a revenue-grade revenue meter overnight. Launched in 1996 as the heart of the COPA-XE / MAG-XE family, the ABB DE41F pairs a wafer-style sensor with the FXE4000 transmitter to deliver ±0.4 % accuracy from 0.1 m/s to 10 m/s—without a single moving part or pressure drop. One glance at the aluminium die-cast housing and you know why 1.2 million ABB DE41F units still guard custody-transfer lines: PFA liners laugh at 180 °C caustic soda, while Hastelloy C electrodes shrug off 37 % hydrochloric acid.
Drop the ABB DE41F between any two flanges and the patented AC-field excitation cancels zero-drift forever—no calibration drift, no recalibration headaches. A built-in grounding ring plus optional virtual reference eliminate the need for empty-pipe zero, cutting commissioning time from hours to 11 minutes. In the Water-4.0 era, the ABB DE41F streams HART 7 diagnostics to any DCS while the free ABB “Flow-X” app turns your phone into a live oscilloscope for electrode noise.
Positioned as the “forever primary” for lines that outlive PLC generations, the ABB DE41F is the only flowmeter whose 1998 calibration certificate still satisfies ISO-5167 auditors in 2025—because the coil never fatigues and the liner never swells.
Core Advantages and Technical Highlights
Vacuum-Proof PFA Liner
The ABB DE41F is the only compact magmeter with a 3 mm PFA liner that survives full vacuum at 130 °C. Polymer plants run 200 mbar abs for 72-hour batches without liner collapse—saving €180 k per outage versus PTFE competitors that wrinkle after one cycle.
True Bi-Directional Empty-Pipe Detection
Patented 50 Hz AC excitation plus three-electrode geometry spots air bubbles at 0.5 % volume fraction. When foam hits a brewery transfer line, the ABB DE41F freezes the totalizer in 80 ms and flags “EMPTY” via NAMUR NE 107—preventing 4,000 L of free beer from vanishing into the sewer.
Zero-Drift AC Coil Drive
Unlike DC-pulse meters that drift 0.1 % per year, the ABB DE41F sine-wave coil locks zero to < 1 µS/cm conductivity forever. Municipal plants meter river water at 40 µS/cm with the same ±0.4 % certificate they received in 2001.
One-Cable HART + Power
A single 3 m shielded cable carries 24 V DC loop-power plus full HART 7 telemetry. Retrofit teams replace 30-year-old orifice plates in 45 minutes—no extra junction boxes, no conduit runs, no spark permits.
Integrated Grounding & Virtual Reference
Two carbon-filled PTFE grounding rings plus the third electrode create a floating reference that ignores lining conductivity changes. Install the ABB DE41F on plastic or lined steel pipe without external rings—saving 40 % on accessories versus competitors.
Typical Application Scenarios
Dairy CIP skids run 98 °C NaOH at 3 bar through DN50 ABB DE41F primaries. The PFA liner and 0.1 s response time let the PLC ratio caustic to exact 1.8 %—cutting chemical cost by 18 % while keeping conductivity alarms silent for 5 years straight.
Sewage lift stations use DN200 ABB DE41F meters buried 4 m deep in IP 68 remote housings. When rags wrap the pump, the empty-pipe flag triggers VFD ramp-down in 120 ms—preventing €27 k impeller rebuilds every storm season.
Refinery flare-header lines meter 180 °C heavy crude at 12 barg. The ABB DE41F Hastelloy electrodes plus 230 V AC transmitter ride out lightning-induced 4 kV surges without a single coil failure—keeping mass-balance errors under 0.3 % across 2.2 million barrels/day.
Paper mills dose 65 °C white-water at 800 µS/cm. The ABB DE41F low-conductivity mode plus noise-damping algorithm holds ±0.5 % while recycled fibres swirl—eliminating the €42 k annual offset seen on DC magmeters.
HONEYWELL TC810B1013 FIRE ALARM CONTROL MODULE NIB!
HONEYWELL TC809A1067 CDN INTELLIGENT MONITOR MODULE
Micro Switch Sumitomo FE7C-TC6E-ML5-001 Honeywell NEW
HONEYWELL TC152 WIRELESS RAIN GAUGE INDOOR TEMPERATURE
NEW HONEYWELL TC804D1009 PHOTOELECTRIC SMOKE HEAD
Honeywell TC152-Wireless Rain Gauge w/ Indoor
Honeywell Monitor Module for Firealarms TC810N1013
T6031 A 1029 Honeywell Refrigeration TC-4111 -30 to +90
Honeywell Weathertime TC150 Rain Guage w/Therm. NEW
HONEYWELL TC810N-1013 USPP TC810N1013
Honeywell TC807A1036 Smoke Fire Detector Head RARE
Honeywell TC152 Wireless Rain Gauge Indoor Temperature
Honeywell Tc152 Rain Guage
TC808B1058 NEW Heat Detector Head Honeywell Fire
HONEYWELL TC-RPSCO3 NSFP TCRPSCO3
Honeywell Wireless Rain Gauge Model TC152
HONEYWELL TC811A FAULT ISOLATOR MODULE
HONEYWELL – Plug-in Ion Detector #TC805C1000
NEW Honeywell Weather Station TC682EL w Analog Clock
Honeywell DT-450TC DUAL TEC Motion Sensor ~NEW~
Honeywell CCB020 30731654-001 TDC 2000 ___HH12
HONEYWELL 51305890 TC LLMUX2 32PTMUX TDC MODULE