Product Overview
The DECS-200-2L + ICRM-15 is a highly advanced and integrated excitation control solution from Basler Electric, designed to provide enhanced voltage regulation, fault protection, and system flexibility for medium to large-scale generator applications. Combining the capabilities of the DECS-200-2L excitation control unit with the ICRM-15 input/output (I/O) control and monitoring module, this system offers comprehensive generator control, fault diagnostics, and real-time monitoring in a single, unified platform. The DECS-200-2L + ICRM-15 combination is perfect for applications in power generation plants, industrial power systems, and critical infrastructure, where precise and reliable voltage control is essential.
The DECS-200-2L provides digital excitation control for synchronous generators with superior voltage regulation and robust protection features, while the ICRM-15 module offers additional I/O expansion and enhanced diagnostic capabilities. Together, the system offers precise control over excitation currents, ensuring stable generator output even under fluctuating load conditions. The DECS-200-2L + ICRM-15 is designed to integrate seamlessly with existing generator control systems, offering a cost-effective solution for both new installations and retrofits.
This integrated system supports multiple communication protocols, including Modbus RTU and CANopen, allowing easy integration with other control systems and offering real-time data exchange for improved system diagnostics and monitoring. Whether used in large-scale power plants or smaller industrial systems, the DECS-200-2L + ICRM-15 ensures reliable, stable operation, reducing downtime and enhancing overall system efficiency.
Technical Specifications
| Parameter Name | Parameter Value |
|---|---|
| Product Model | DECS-200-2L + ICRM-15 |
| Manufacturer | Basler Electric |
| Product Type | Digital Excitation Control System + I/O Module |
| Supply Voltage | 120/240 VAC, 50/60 Hz |
| Control Type | Digital Microprocessor Control |
| Communication Protocol | Modbus RTU, CANopen |
| Voltage Regulation Accuracy | ±0.25% |
| I/O Module Type | ICRM-15 Input/Output Module |
| Operating Temperature | -20°C to +70°C |
| Dimensions (DECS-200-2L) | 6.5″ x 5.5″ x 3″ (165mm x 140mm x 75mm) |
| Dimensions (ICRM-15) | 8″ x 6″ x 4″ (203mm x 152mm x 102mm) |
| Mounting Type | Panel Mount |
| Protection Features | Overvoltage, Undervoltage, Field Loss |
| Weight (DECS-200-2L) | 1.5 kg |
| Weight (ICRM-15) | 2.0 kg |
Main Features and Advantages
Precision Voltage Regulation:
The DECS-200-2L + ICRM-15 ensures precise voltage regulation with a high level of accuracy (±0.25%), maintaining stable generator output even under fluctuating load conditions. This precision helps prevent power quality issues, protecting connected equipment and improving overall system performance. By stabilizing voltage, it enhances the safety and reliability of both the generator and the entire power distribution system.
Comprehensive Protection:
With built-in overvoltage, undervoltage, and field loss protection, the DECS-200-2L + ICRM-15 protects the generator from common electrical faults that could damage the system. This comprehensive protection is vital in critical applications where downtime can result in significant losses. The system’s fast fault detection and response capabilities ensure that corrective actions are taken immediately, preventing potential damage and minimizing downtime.
Expanded I/O and Monitoring:
The addition of the ICRM-15 I/O module provides enhanced input and output capabilities, allowing the DECS-200-2L + ICRM-15 to interface with a wider range of sensors, actuators, and control systems. This modular approach enhances system flexibility, enabling the unit to be tailored to specific application needs. Real-time monitoring and diagnostics from the ICRM-15 module offer detailed insights into system performance, fault conditions, and event logs, enabling operators to make informed decisions and improve system reliability.
Seamless Communication Integration:
The DECS-200-2L + ICRM-15 supports industry-standard communication protocols, including Modbus RTU and CANopen, making it easy to integrate with other control systems, SCADA systems, and monitoring solutions. The ability to exchange real-time data improves system diagnostics and allows for centralized monitoring and control, improving operational efficiency and reducing the need for manual intervention.
Easy Installation and Customization:
Both the DECS-200-2L and ICRM-15 are designed for easy installation in standard panel-mount configurations. The compact size of both modules allows for flexible integration in generator control panels, reducing the need for additional space and simplifying system setup. Additionally, the ICRM-15 module allows for future system expansion, enabling the unit to adapt to evolving application requirements.
Application Field
The DECS-200-2L + ICRM-15 is ideal for a wide range of applications requiring precise generator excitation control and expanded I/O functionality. It is particularly well-suited for medium to large-scale power plants, industrial facilities, and critical infrastructure systems where reliable voltage regulation and robust protection are essential.
In power generation plants, the DECS-200-2L + ICRM-15 stabilizes generator output and ensures smooth, consistent power delivery to the grid. The system’s advanced protection features prevent electrical faults that could disrupt power production, ensuring continuous operation and minimizing downtime. The ICRM-15 I/O module provides the flexibility to interface with various sensors and actuators, making the system adaptable to complex power plant configurations.
In industrial settings, the DECS-200-2L + ICRM-15 ensures reliable operation of synchronous generators that power large machinery and equipment. The system can be used in manufacturing, oil and gas, and other heavy industries where generator control is critical for maintaining operational efficiency. The DECS-200-2L + ICRM-15 also finds application in backup power systems, stabilizing the generator output during emergency or standby power conditions, ensuring that critical loads are maintained during power outages.
Related Products
- DECS-100: A more cost-effective excitation controller for smaller generator systems, the DECS-100 offers basic voltage regulation without the advanced features of the DECS-200-2L, making it ideal for less demanding applications.
- DECS-250: A more advanced version of the DECS-200-2L, the DECS-250 offers greater power handling capabilities and additional protection features, suitable for larger generator systems.
- ICRM-30: A higher-capacity I/O module designed for larger-scale generator control applications. The ICRM-30 expands on the ICRM-15 with more I/O channels and enhanced diagnostics.
- DECS-300: The DECS-300 is designed for high-power applications, providing advanced control, monitoring, and protection features for large-scale generators and power plants.
- Basler BE1-11: A protective relay system that can be used alongside the DECS-200-2L + ICRM-15 to provide additional protection and fault detection capabilities in generator systems.
Installation and Maintenance
Pre-installation preparation:
Before installing the DECS-200-2L + ICRM-15, ensure that the power supply meets the unit’s required 120/240 VAC, 50/60 Hz specifications. The installation area should be clean, dry, and well-ventilated to prevent overheating. The modules are designed for panel mounting, and proper space should be allocated in the control panel. Verify that all communication and power cables are securely connected, and ensure that the system is properly grounded to prevent electrical issues.
Maintenance recommendations:
Regular maintenance for the DECS-200-2L + ICRM-15 involves checking the wiring connections, verifying the system’s performance using diagnostic tools, and cleaning the ventilation openings to prevent overheating. The I/O modules should be inspected periodically to ensure that they are functioning correctly, and firmware updates should be applied as necessary to ensure optimal performance. Calibration and verification of protection settings (overvoltage, undervoltage) should be performed regularly to maintain system reliability.

Tokyo Electron Yamanaski P-12XL AQA-K09-TYP2 Chiller
Perkin-Elmer 3030 Atomic Absorption Spectrometer Zeeman
Kensington Laboratories Inc. 8500 X-Y Motorized Stage
Neopost SI-70 SI70 Advanced Mailer Mailing System
Seiko Seiki STP SCU-H1000C Turbo Molecular Pump Control
Saint-Gobain AstiPure PFD3 333S Controlled Flow Pump
Saint-Gobain AstiPure PFD3 322AI Controlled Flow Pump
Young Eng. Mfg. Inc. 40BSA-27 Surge Suppressor Tank
K&S Kulicke & Soffa 1471 Automatic Wedge Bonder
Advanced Energy / ASM PDP3500 Pulsed Plasma Controller
Kevex 7000 Wafer Analysis System & Control Unit
Garb-el Automatic Feed Bedding Disposal AL-50-P
Perkin-Elmer 3B Lambda UV/VIS Spectrophotometer
Hugle Electronics 411N1 Controller w/ 410N1 Ionizer Bar
Saint-Gobain AstiPure PFD3 333SI Controlled Flow Pump