- Model: MVC3002-4001
- Brand: Converteam (ALSTOM/GE Power Conversion lineage)
- Series: MV3000 / ALSPA MV3000 Delta
- Core Function: User signal interfacing between plant and CDC controller
- Type: User I/O Termination Panel
- Key Specs: 50-way ribbon cable connection to controller, terminal blocks for analog/digital I/O, supports standard MV3000e control signals
Converteam MVC3002-4001 is the user I/O termination panel for ALSPA MV3000 Delta drive systems. It provides screw terminals for connecting plant signals—analog references, start/stop commands, status feedbacks, faults—to the Common Drive Controller (CDC like MVC3001-4003).
Mount it near the controller for short ribbon cable runs. Handles standard MV3000e I/O: typically analog in/out for speed/torque, digital for control, relays for alarms. Kit includes the panel, 50-way ribbon, clamp/base. In legacy setups (wind, pumps, industrial), it centralizes field wiring to avoid direct controller exposure. Discontinued—GE/Avid Controls license parts; confirm wiring diagram from T1689/T1693 before install, especially if swapping in air vs liquid-cooled configs.
- Interfaces all user I/O signals reliably via ribbon to CDC—reduces wiring errors in cubicle builds
- Test report provided: serial/label check, visual (no corrosion, terminal damage, dust), continuity mapping on all terminals, ribbon connection verify, 24-hour powered bench with sim signals and photos
- Clear upgrade path—mounts same as original; ribbon kit ensures plug-compatible link to MVC3001 CDC
- Not recommended for standalone use—requires MV3000 CDC and drive modules; migrate to newer GE converters for full system support
- Supports full MV3000 I/O suite per technical manuals (analog ±10 V/4-20 mA, digital 24 V typical)
- Insulation/continuity >10 MΩ at 500 V where applicable; full verification with setup photos and terminal map
Frequently Asked Questions
What does the MVC3002-4001 do in an MV3000 Delta system? It’s the termination point for all external user signals (analog speed ref, digital start/stop, fault relays) wired to screw terminals, then ribbon-linked to the CDC controller. Keeps field wiring organized away from the main controller board.
Can I install this as a direct replacement in an existing MV3000 setup? Yes—same footprint and ribbon interface. Photograph existing ribbon routing, terminal labels, and wiring before disconnect. Mount close to CDC per datasheet; test continuity end-to-end on arrival before powering up.
What’s included with the MVC3002-4001 panel? Panel itself, one 50-way ribbon cable, cable clamp/base, and data sheet. No other cables or power supplies—refer to T1689/T1693 for full system connections.
Is this new surplus or refurbished? Condition: New Surplus (New Original, not refurbished). From OEM excess or decommissioned spares—no field exposure.
Cognex NotchMax IS5100 IS5100-NMAX-KT00
Cognex 200-0024 4400 Video Frame Grabber (VDE BUS Boar
DVT / COGNEX LEGEND 510MR + TAMRON 25mm LENS + ILLUMNTR
Cognex 4400/VME
Cognex 800-5885-1 I/O Connection Module
JDS FITEL TB2500-EC TUNABLE ETALON CONTROLLER
HP 6206B DC Power Supply ,0-60V,5A / 0-30V,1A
HP 6281A DC Power Supply ,0-7.5V,0-5A
LEICA MICROSCOPE zoom 2000,Z45 L , excellent condition
TEKTRONIX ST2400 SDH/SONET SET WITH OPTION
FOTEC S FS370 238 FIBER POWER SOURCE
Agilent 37718A Omni-Ber 718 Communications Performance
OptiSpec EKE Light source For Video Microscope QTYS 5
HP 81689A Tunable Laser module.w opt 072
Agilent 83481A Dual rate optical/electrical plug-in Opt
EFD Model 1500XL Adhesive Dispenser
TEKTRONIX ST2400 SDH/SONET SET WITH OPTION