- Model: MVC3003-4025A
- Brand: CONVERTEAM (now GE Vernova / GE Power Conversion)
- Series: ALSPA MV3000 DELTA
- Core Function: Switch Mode Power Supply (SMPS) providing auxiliary and control power
- Type: High-voltage input SMPS module (slave configuration)
- Key Specs: 575-690 VAC input, enhanced overvoltage protection (up to 1200 V DC link trip), compatible with MV DELTA transistor bridges (e.g., MVD300-4601, MVDL643-4701)
Key Technical Specifications
- Input voltage: 575-690 VAC (3-phase)
- Output: Multiple DC rails for control, gate drives, fans, etc. (exact voltages per OEM manual; typical low-voltage aux + high-voltage isolation)
- Overvoltage protection: Enhanced capability, trips at 1200 V max DC link
- Configuration: Slave SMPS (often paired with master or used in multi-module setups)
- Compatibility: MV3000 DELTA series inverters (air/liquid cooled)
- Operating temperature: Typical -25 to +55 °C (verify enclosure rating)
- Mounting: Modular assembly in drive cubicle, bonded to DELTA components
- Features: Overvolt detect integrated, compatible with specific transistor bridge types
- Pollution degree: 2 (standard for MV industrial)
- Status: Discontinued; limited spares – check Avid Controls or GE Vernova for reman options
Product Introduction
The CONVERTEAM MVC3003-4025A supplies switched-mode power to control circuits, gate drivers, and auxiliaries in ALSPA MV3000 DELTA medium-voltage inverter systems.
It handles 575-690 VAC input with built-in overvoltage safeguards that trip at higher DC link levels (1200 V max), suiting wind turbine converters, pumps, or compressors in industrial/marine setups. As a slave SMPS, it supports modular drive configs where multiple power sections share aux power. In field replacements, match input rating and cubicle layout — enhanced protection reduces nuisance trips from grid transients. Always pull the specific manual (e.g., MVC3003-4025/MVC3003-4030 doc) and check DC link compatibility before install.
Key Selling Points & Differentiators
- Input range 575-690 VAC covers common MV supplies; handles transients better than narrower-range PSUs
- Enhanced overvoltage to 1200 V DC link trip level adds security in regenerative or unstable grid applications
- Slave design allows scalable multi-bridge setups — more flexible than integrated single PSUs in smaller drives
- Test report includes input power-up, output voltage/ripple checks, overvolt simulation, 24-hour burn-in; photos of assembly, labels, and test waveforms available
- Not recommended for non-DELTA MV3000 variants or systems without matching transistor bridges — verify bridge type (e.g., MVD300 series)
- Aligns with typical IEC/EN standards for MV drive auxiliaries in pollution degree 2 environments
Vytran PTR-100 Automatic Fiber Recoater
WaveSplitter 1×2 C-band Fused Fiber Coupler
DiCom SCD1263 Forward Pump Islator
JDS Fitel P/N WD1414-Z00033
Intermec MicroBar 9710 Decoder for Barcode Scanners
Visual Inspection / Alignment Station
Ando AQ8423Z Optical Amplifier Analyzer
Philips PM5193-M Programmable synthesizer / function ge
ADE 3401 Capacitive probe, 115V, 50/60Hz.
Hitec 3201-SP Proximic capacitive reactance tester
LeCroy 9374L Oscilloscope, 1GHz,
INO FAD-180 Benchtop Erbium-Doped Fiber Amplifier
Premises,Fiber NCA-8021-001 SM SBJ 13000 FT