- Model: MVI56-101M
- Brand: ProSoft Technology
- Series: MVI56 (ControlLogix in‑chassis)
- Core Function: IEC 60870-5-101 master for serial substations
- Type: IEC 60870-5-101 Master Communication Module
- Key Specs: ControlLogix slot, 800 mA @ 5.1 V, up to 32 serial devices (typical)
For detailed sizing and hazardous‑area acceptance, always confirm against the latest ProSoft datasheet and installation manual for MVI56‑101M.
Product Introduction
From a ControlLogix perspective, the ProSoft MVI56‑101M is the in‑rack way to talk IEC 60870‑5‑101 to legacy substations and protection devices without adding an external gateway. It occupies a single ControlLogix slot and acts as an IEC‑101 master, presenting data to the PLC via a defined internal database.
Engineers pick the MVI56‑101M when they need the ControlLogix CPU to poll multiple IEC‑101 outstations—often up to a few dozen serial devices on multi‑drop links—while keeping communication timing decoupled from the PLC scan. Backplane draw is 800 mA at 5.1 V plus about 3 mA at 24 V, with an operating range of 0 to 60 °C, so you must check both rack power and cabinet temperature before you sign off the design.
Key Selling Points & Differentiators
- IEC 60870‑5‑101 master in a single ControlLogix slot, avoiding an extra DIN‑rail gateway and separate power supply in already crowded protection panels.
- Typical applications interface up to around 32 IEC‑101 serial devices from one ControlLogix processor, which is enough for many substation and RTU consolidation projects.
- Backplane current of 800 mA @ 5.1 V and 3 mA @ 24 V means you must keep ~20% headroom on the 5 V rail; ignoring this is a common cause of random communication issues in mixed ControlLogix racks. (Typical figure, verify exact load in datasheet.)
- Compared with DNP3 or Modbus modules, IEC‑101 master is better aligned to European and utility environments that standardize on IEC 60870‑5‑101; trying to “shoehorn” those sites onto other protocols often introduces avoidable conversion layers.
- Not recommended for greenfield designs where IEC‑104 over TCP is already mandated; in those cases, go straight to an IP‑based solution and keep MVI56‑101M for serial legacy catch‑up only. (Check project spec and IEC‑104 requirements.)
- For stock spares, you can treat “New Original (New Surplus)” or “Refurbished (tested)” as viable options only if they come with a functional test report (power‑on, IEC‑101 exercise, 24+ hour run) and photos of the actual module.
Corning Leaf (R)Optical Bare Fiber 8.8 km
HP 10430A 10:1 Probe
Burleigh PCS-6000 / 6100 Controller and fixture
AGILENT / HP 8166A Lightwave Multichannel System
NATIONAL INSTRUMENTS 763061-03 REV C X2 GPIB CABLE qty2
FIS F1-8513HR OV-PM Optical Power Meter
Hewlett Packard 3776B PCM Test Set
Hewlett Packard 8970A Noise Figure Meter 10MH-1.5GH
TEKTRONIX ST2400A SDH/SONET SET
Alpha FIT221B-3/64-BK Heat Shrinkable Sleeve 100′
Alpha FIT221B-1/16-BK Heat Shrinkable Sleeve 100′
AP SOIC CLIP SET LTC 20 Test Clips
Antona Corp ANC-9068 SMD Wire-Wrap Prototyping Adapter
Antona Corp ANC-9068J SMD Wire-Wrap Prototyping Adapter
Spirent NetCom Smartbits SX-7410B Spirent SX7410B
Thomas &Betts 50 pieces part # fsps-1-40-c
AP SOIC CLIP SET LTC 24/3 Test Clips