Sale!

Alstom MVAA21 T1BA0793A | OEM Electromechanical Relay Unit

Original price was: $7,686.00.Current price is: $3,454.00.

  • Model: MVAA21 T1BA0793A
  • Brand: Alstom (now GE Grid / legacy AREVA)
  • Series: MVAA Auxiliary Relay Series
  • Core Function: Provides auxiliary switching and signaling in protection circuits
  • Type: Electromechanical Auxiliary Relay
  • Key Specs: Multiple NO/NC contacts; manual reset flag; panel mount case
  • ⚠️ Discontinued — limited stock
  • Condition: New Original (New Surplus) — not refurbished
Category: SKU: MVAA21 T1BA0793A ALSTOM
  • Email:sales@sxrunsheng.cn
  • Phone:+86 15340667322
  • Whatsapp:+86 15340667322
  • Description

    Alstom MVAA21 T1BA0793A is an electromechanical auxiliary relay used in generator and substation protection schemes, typically installed in switchgear panels to provide contact multiplication, interlocking, and trip signaling functions.

    In field deployments, MVAA relays sit between primary protection relays and breaker control circuits, handling logic such as trip distribution and alarm signaling. Expect fast response mechanical contacts and simple maintenance, but no digital diagnostics — this is old-school hardware, and honestly, that’s why many plants still trust it.

     

    Phase 1 — Pre-Installation (est. 10 min)

    Isolate control power. Wait 5 minutes.
    Tools: insulated screwdriver, torque driver, label tags, Fluke 115 multimeter.
    Photograph wiring — especially trip and alarm circuits. Record contact logic (NO/NC).

     

    Phase 2 — Removal (est. 5 min)

    Label each wire clearly.
    Withdraw relay from case (if draw-out type).
    Inspect terminal block and case contacts — oxidation is common in older panels.

     

    Phase 3 — Installation (est. 10 min)

    ESD is less critical here — mechanical relay — but still follow standard practice.
    Confirm model and coil voltage.
    Insert relay fully into case; ensure proper seating.
    Reconnect wiring per photos. Tighten terminals (~0.5 N·m typical).

     

    Phase 4 — Power-On & Testing (est. 15 min)

    Energize control supply.
    Observe mechanical operation — listen for coil pickup.
    Test each contact using multimeter or test lamp.
    Simulate trip signal and verify downstream breaker/control response.
    Run ≥30 min stable operation and log results.

    Troubleshooting quick-reference

    • No pickup → check coil voltage and supply polarity
    • Contacts not switching → inspect mechanical linkage or worn contacts
    • Intermittent operation → check terminal tightness and oxidation

    Alstom MVAA21 T1BA0793A | OEM Electromechanical Relay Unit

    Leybold Trivac Rotary Vane Vacuum Pump D65BCS NEW

    Shimadzu Vacuum Turbopump TMP 2001-LME new

    AHF80SS NASH VACUUM PUMP, 5 HP

    2BE1253 SIEMENS VACUUM PUMP C/S 125 HP

    2BE1253 SIEMENS VACUUM PUMP C/S 125 HP

    TC5 NASH VACUUM PUMP, 25 HP

    H7 NASH VACUUM PUMP, S/S

    Used- Busch Single Stage Cobra Dry Screw Vacuum Pump, m

    Used- Busch Single Stage Cobra Dry Screw Vacuum Pump, m

    Roots Vacuum Blower – Model 1442 PGS-HVB

    EBARA A10S Dry Vacuum Pump, Surplus New: 1yr warranty

    Varian TV 551 MacroTorr Turbo Vacuum Pump Rebuilt
    Varian Factory Rebuild with Six Month Warranty
    One-day shipping available

    EBARA ET-2500WS Turbo Vacuum Pump, 2500 WS, Surplus New
    One-day shipping available

    Edwards iQDP40 Vacuum Dry Pump 1yr warranty