AO2000-URAS26 33854719 ATO11-021 ABB

Related Product Combination Solutions:

The ABB AO2000-URAS26 is part of a complete system and can be combined with other components:

  • AO2000 Central Unit: The main system chassis that provides power, data processing, and communication for the AO2000-URAS26 and other modules.
  • Magnos27: A paramagnetic oxygen analyzer module that works in synergy with the URAS26 for combustion control applications where both oxygen and CO are critical parameters.
  • Caldos25: A thermal conductivity analyzer, often used with the URAS26 to measure gases like hydrogen or helium, providing a more complete picture of the gas stream.
  • LS25: A laser analyzer module for specific gases like NH₃ or H₂S. This can be integrated with the URAS26 to create a multi-component analysis solution for complex process streams.
  • SCC-C: A sample gas cooler, an external unit used to prepare hot and moist gas samples, ensuring they are at the correct temperature and humidity for the analyzer modules, which protects the instruments and ensures accuracy.

Installation, Maintenance, and Full-Cycle Support:

The AO2000-URAS26 is designed for easy installation, simply sliding into a designated slot in the main central unit. Its robust design and low drift minimize the need for frequent maintenance. While periodic calibration is necessary, its stable NDIR technology ensures long intervals between these procedures. The modular nature of the system simplifies troubleshooting and part replacement, ensuring minimal downtime.

Category:
  • Email:sales@sxrunsheng.cn
  • Phone:+86 15340667322
  • Whatsapp:+86 15340667322
  • Description

    Description:

    The ABB AO2000-URAS26 33854719 ATO11-021 is an infrared photometer analyzer module, specifically a non-dispersive infrared (NDIR) gas analyzer, designed for the ABB Advance Optima series. This module is used for the continuous and precise measurement of various gas components, such as CO, CO₂, SO₂, NO, and CH₄, and is widely utilized in industrial process control and emissions monitoring due to its high selectivity and stability. The part number ATO11-021 indicates a specific configuration, likely related to the measurement range or other technical specifications.

    Application Scenarios:

    In a power generation facility, maintaining the optimal air-fuel ratio in a boiler is essential for maximizing energy efficiency and minimizing harmful emissions. Monitoring flue gas composition is a critical part of this process. The AO2000-URAS26 is the ideal solution for this task. It is installed to continuously measure gases like carbon monoxide (CO), which is an indicator of incomplete combustion. By providing operators with real-time, accurate CO data, the AO2000-URAS26 allows them to make immediate adjustments to the combustion process, ensuring a more efficient burn, reducing fuel waste, and helping the plant meet stringent air quality standards. This proactive control not only lowers operational costs but also enhances the facility’s environmental performance.

    Parameter:

    Main Parameters Value/Description
    Product Model AO2000-URAS26 33854719 ATO11-021
    Manufacturer ABB
    Product Category Non-Dispersive Infrared (NDIR) Analyzer Module
    Measurement Principle NDIR Photometry, offering high selectivity and stability.
    Gases Measured Configurable for CO, CO₂, SO₂, NO, CH₄, and others.
    Response Time Fast, with a typical T₉₀ < 5 seconds.
    Measurement Range Varies based on configuration; specified by part number ATO11-021.
    Cross-Sensitivity Minimal, due to advanced detector technology.
    Output Signal 4-20 mA analog output, with digital communication via the central unit.
    Operating Conditions Integrated within the climate-controlled AO2000 Central Unit.
    Calibration Requires zero gas and span gas for calibration.
    Approvals ATEX, IECEx, or other certifications depending on the model, for hazardous areas.

    Technical Principles and Innovative Values:

    • Advanced Double-Layer Detector: The AO2000-URAS26‘s core innovation lies in its double-layer infrared detector. This design significantly enhances the analyzer’s selectivity by using a reference cell and a measurement cell, allowing it to precisely identify and quantify the target gas while effectively minimizing cross-interference from other gases in the sample. This ensures a highly accurate and reliable measurement, which is crucial for critical processes.
    • Low-Maintenance and Robust Design: The module’s compact, rugged construction is built to withstand demanding industrial environments. The stable NDIR technology reduces measurement drift, which means less frequent calibration and overall lower maintenance requirements compared to other gas analysis technologies.
    • Fast and Reliable Feedback: With a rapid T₉₀ response time, the AO2000-URAS26 provides near-instantaneous feedback on gas concentration changes. This speed is essential for real-time control systems, enabling operators to make rapid, data-driven decisions that can prevent process deviations, improve efficiency, and enhance safety.

    AO2000-URAS26 33854719 ATO11-021 ABB

    Application Cases and Industry Value:

    A major chemical manufacturer was modernizing its process for producing ethylene oxide, a highly sensitive process where precise gas composition control is paramount. They integrated the ABB AO2000-URAS26 to continuously monitor CO₂ levels in their reactor’s gas stream. The analyzer’s high accuracy and stability allowed them to maintain a tighter control loop, leading to a 3% increase in product yield and a noticeable reduction in energy consumption. The plant manager specifically highlighted the analyzer’s reliability and low maintenance, stating it had “become the workhorse of our gas analysis system.”

    NAiS Panasonic KT9 Temperature Controller NIB

    OMRON DIJITAL TIMER H5CN-YCN H5CNYCN NEW ( NIB !!! )

    Primatics Motion Controller LNC !!!

    Parker Compumotor OEM Power Supply OEM300

    Hayashi Fiber Optic Light Guide 3 Way LNC!

    NICE! MITSUBISHI AX41C OFFER!!!!

    NAiS Panasonic KT4 Temperature Controller NIB

    SUNX DP-101 DIJITAL PRESSURE SENSOR NIB

    New OMRON CS1W-II102 I/O Interface Unit Offer!

    DEL-TRON Positioning Stage LS3-1 Nice !!!

    NIB Keyence FS-V12 Sensor Photoelectric Amplifier

    OMRON STAR-DELTA TIMER H3CR-G8EL 6-120 S NEW