Sale!

DEIF MTR-4 | 4x Analog/RS485 Industrial Transducer In Stock

Original price was: $7,989.00.Current price is: $5,674.00.

  • Model: MTR-4 (DEIF)
  • Brand: DEIF A/S
  • Series: MTR-4 Multi-Transducers
  • Core Function: Measures and communicates AC electrical network parameters
  • Type: Multi-Transducer / Power Monitoring Module
  • Key Specs: Voltage/current sensing; RS485 Modbus; programmable analogue outputs
  • Condition: New Original (New Surplus) — not refurbished
Category: SKU: MTR4 DIEF
  • Email:sales@sxrunsheng.cn
  • Phone:+86 15340667322
  • Whatsapp:+86 15340667322
  • Description

    DEIF MTR-4 is a programmable multi-transducer used in industrial electrical power monitoring to measure RMS voltage, current, power, energy, frequency, and THD across single- and three-phase networks. It consolidates multiple electrical parameters into analog outputs and RS485 Modbus data for PLC/SCADA systems.

    Configured via USB or RS485 using DEIF’s M-Set software, this device supports up to four analog outputs (configurable ranges) and high accuracy (class 0.5/0.4) at fast refresh rates (~50 ms). Typical lead time for new stock is 4–8 weeks; surplus inventory may ship within 1–2 weeks once ordered.

     

    Phase 1 — Pre-Installation (est. 10 min)

    Lock out/tag out power. Wait 5 min for discharge. Tools: insulated screwdrivers, torque driver, Fluke 115 multimeter, label tags. Record existing panel wiring. Check network type (single vs three-phase) and transformer ratios for current/voltage inputs.

     

    Phase 2 — Removal (est. 5 min)

    Label each conductor before loosening. Unmount the MTR-4 from DIN rail; do not twist while removing. Inspect terminals for corrosion or embedded ferrite residues.

     

    Phase 3 — Installation (est. 10 min)

    Wear ESD protection first. Confirm part number. Mount on 35 mm DIN rail. Tighten supply and measurement terminations to ~0.5 N·m. Connect RS485 shielded twisted pair for Modbus; tie shield per your site grounding scheme.

     

    Phase 4 — Power-On & Testing (est. 15–20 min)

    Apply universal auxiliary supply (24–250 V DC or 48–230 V AC). Observe PWR LED. Connect via USB to DEIF M-Set to configure measurement ratios (CT/VT), output scaling, and Modbus registers. Poll values in the host PLC/DCS to verify correct scaling. Run stability checks for 15–30 min and log results.

    Troubleshooting quick-reference

    • No RS485 comms → check baud/parity, polarity, termination resistor
    • Incorrect measurements → verify CT/VT ratio settings
    • No analog outputs → confirm output range configs in software

    DEIF MTR-4 | 4x Analog/RS485 Industrial Transducer In Stock

    HONEYWELL RM7890 A 1056 FLAME AMPLIFIER

    Rexroth 1″ Filter R432003072 AS5-FRE-N100-GA​U NEW

    NEW BUSSMAN JCL-12R FUSE 230 AMP JCL12R 230 A 230A

    Reliance DC1-62U DC1 VS DRIVE DC162U 1-2 HP CONTROLLER

    AB Allen Bradley 1772-LWP ser D MINI-PLC-2/17 PROCESSOR

    Allen Bradley Starter 100-A45NZ*3 100-A45N 100-A45NZ3

    Rexroth 1″ Filter R432003067 AS5-FRE-N034-GA​U NEW

    Rexroth Indramat VE102 VE 102 A1 VE VE102A1 VE102AI

    Agastat Timer 2422AC .8-15 SEC 120V Coil

    Bielomatik STEURGER 30063107 Minimal Mengen Schmierun

    NEW GE IC3600 IC3600LINA1D1B I C3600LINA NEW

    Brooks Flow Meter Totalizer Tri-10 9853AC2A1B1A1A2 20vd

    Compumotor Corp Motor Drive Controller M5710211 C-B

    RELIANCE ELECTRIC 0-51845-2 0 51845 2 0518452

    Square D i-line busway pq4203 30A pq-4203 fusible

    Nicolet 4094C Digital Oscilloscope & F-43 & 4562 Module

    NEW PANALARM RILEY PIAF1T125DC8GP 090-0062-5-03-N

    Modicon Schneider Remote I/O Processor AS-P451-622 200

    Sew Eurodrive AC Drive C2302.0 3ph 2.0kva 2.0 kva