Description
GE Multilin F35 is a universal feeder protection relay providing integrated protection, control, monitoring, and metering for up to six distribution feeders on electrical networks. It supports IEC 61850 communications, flexible logic, waveform capture, and advanced diagnostic capabilities for substation and industrial applications.
Featuring high-speed communications (Ethernet/serial), programmable FlexLogic™, and extensive built-in metering, the F35 simplifies feeder management and reduces field device counts compared with discrete protection and metering devices. Lead times for new units typically range from 4–8 weeks when not stocked; surplus inventory ships faster.
Phase 1 — Pre-Installation (est. 15 min)
De-energize feeder panels and wait 5 min to discharge. Tools: insulated screwdrivers, torque driver, ESD wrist strap, multimeter (Fluke 115), label tags. Photograph existing wiring and CT/VT connections. Confirm CT/VT ratio, interface modules, and power supply range.
Phase 2 — Removal (est. 10 min)
Label all conductors before loosening terminations. Remove any protective covers. Unmount the relay from panel or rack without torque on wiring. Inspect CT/VT terminations and connector pins for corrosion or damage.
Phase 3 — Installation (est. 15 min)
ESD protection first. Seat the F35 relay in its panel cut-out or rack slot. Tighten screws to OEM torque spec. Connect CTs, VTs, digital I/O, and comm links per wiring diagrams. Confirm shield terminations and ensure correct grounding.
Phase 4 — Power-On & Testing (est. 30 min)
Apply correct auxiliary power. Observe status LEDs and front panel indicators. Use EnerVista UR Engineer or host SCADA to configure protection settings, CT/VT ratios, and FlexLogic. Test each feeder path, perform secondary injection tests, and log results. Run >30 min of stable operation and enter into maintenance record.
Troubleshooting quick-reference
- No comms → confirm Ethernet/IP settings and switch config
- False trips → verify CT polarity and ratio settings
- Missing metering → check VT connections and scaling factors

Roots Vacuum Pump FRU2880 NIB
NEW BOC Edwards iF-1800 (iF1800) Dry Vacuum Pump
Edwards BOC iL600 Dry Semiconductor Vacuum Pump
Edwards BOC iL600N Dry Semiconductor Vacuum Pump
Leybold Oerlikon TurboVac MAG W 1300 C Turbo Pump
Expedited shipping available
Edwards iL600N Vacuum Dry Pump Rebuilt
Industrial Vacuum System
Ebara AAS70WN Refurbished
Leybold MAG W 1300 Turbo Pump; DRIVE digital Controller
Sold tested as set with cables and a one year warranty.
Seiko Seiki STP-H2000C Vacuum Turbo Pump Rebuilt
Leybold MAG W 2200 Turbo Pump
Leybold MAG 2000 C Turbo Pump
PFEIFFER DRY VACUUM PUMP PK T11 906 UNIDRY 050-4NC
Varian TV801 (ISO) Turbomolecular Vacuum Pump 790.0 LPS
CL3002 NASH VACUUM PUMP, 200 HP
CL3002 NASH VACUUM PUMP, 200 HP
CL3003 NASH VACUUM PUMP, 200 HP
CL3003 NASH VACUUM PUMP, 200 HP