Sale!

GE Multilin MIVII1000E00HI00 | Factory Sealed Power Protection IED

Original price was: $6,867.00.Current price is: $5,344.00.

  • Model: MIVII1000E00HI00
  • Brand: GE Vernova
  • Series: MIV II Legacy Protection Relays
  • Core Function: Monitors AC voltages; protects against undervoltage/overvoltage and ground overvoltage
  • Type: Digital Protection/Control Relay
  • Key Specs: Four-stage phase UV/OV; two‐stage ground OV; RS-232/RS-485 with Modbus RTU; 110–230 VAC / 110–250 VDC supply
  • Condition: New Original (New Surplus) — not refurbished
Category: SKU: MULTILIN MIVII1000E00HI00 GE
  • Email:sales@sxrunsheng.cn
  • Phone:+86 15340667322
  • Whatsapp:+86 15340667322
  • Description

    GE Multilin MIVII1000E00HI00 is a legacy digital voltage and control protection relay that provides undervoltage (UV), overvoltage (OV), and ground overvoltage protection with configurable I/O and event recording for industrial switchboards, generators, motors, transfer systems, and busbars. Its English text HMI and flexible outputs simplify field configuration and logic assignment.

    Equipped with RS-232/RS-485 communications and Modbus RTU support, it logs 24 events with millisecond timestamps and captures waveform records up to 24 cycles — useful for root-cause analysis on power systems. Typical trip response is <30 ms at 1.2× pickup for the voltage elements.

    Phase 1 — Pre-Installation (est. 10 min)
    De-energize panel. Wait ~5 min for capacitive discharge. Tools: insulated screwdrivers, label tags, torque driver, multimeter, laptop with EnerVista or compatible config software. Photograph existing wiring, pickup settings, and I/O assignments.

    Phase 2 — Removal (est. 5 min)
    Tag all field and control wiring. Loosen panel screws; slide unit straight out. Inspect backplane/connectors for oxidation or bent pins.

    Phase 3 — Installation (est. 10 min)
    ESD strap recommended. Confirm model and supply-range compatibility. Seat relay in rack; torque terminals ~0.5 N·m. Reconnect phase voltage inputs, digital inputs, relay outputs, and communications (RS-485). Maintain consistent shielding and ground practices.

    Phase 4 — Power-On & Testing (est. 15 min)
    Apply supply voltage. Observe LCD and LEDs for status. Use EnerVista or front keypad to set UV/OV pickup levels, delays, programmable outputs, and Modbus parameters. Validate relay outputs with simulated voltage conditions. Run stable protection tests >30 min; log results and update maintenance records.

    Troubleshooting quick-reference:
    • No comms → check RS-485 wiring and termination, baud/parity.
    • False UV trips → verify CT/VT sensor wiring and pickup settings.
    • No trip output → validate programmable output mapping and logic block.

    GE Multilin MIVII1000E00HI00 | Factory Sealed Power Protection IED

    TEL ETCH RF generator rack and Turbo controller rack

    Ebara AA200W Dry Pump-6600 hrs Demo Condition Warranty

    Edwards BOC iLs70 Dry Semiconductor Vacuum Pump

    Quincy QRDT 20 HP Oil-less Air Compressor Model#QRDT-30

    Edwards BOC iL70N Dry Semiconductor Vacuum Pump

    vacuum pump truck

    Body for Nash 1256C liquid ring compressor, SS

    Busch WV-1000 Reconditioned to O.E.M. Specs
    1 Year Warranty Included

    Busch RA0400 Vacuum Pump, Reconditioned to OEM specs.
    1 Year Warranty Included

    SIEMENS VACUUM PUMP, 20 HP, S/S

    New Spencer turbine Vacuum

    Knoll VRF 150/750 Vacuum Rotations Coolant Pump Filter

    Varian Vacuum Ion Pump 912-7022

    Edwards BOC iL70 Dry Semiconductor Vacuum Pump

    NASH H12A VACUUM PUMP TEST #01T1C56 POS NR1 CAST IRON

    RROTARY VANE OIL VACUUM PUMP WIITH MOTOR MVP-540 NIB