HD-8311 TRICONEX

Original price was: $8,874.00.Current price is: $4,458.00.

  • Product Model: HD-8311 (9937871-001)
  • Manufacturer: Triconex
  • System Platform: Tricon v9–v11 and Trident Safety Systems
  • Number of Channels: 32 independent supervised digital outputs
  • Output Voltage: 24 V DC nominal (20.4–28.8 V DC range)
  • Output Current per Channel: 2 A continuous, 6 A inrush for 10 ms
  • Line Monitoring: Short-circuit, open-circuit, and load fault detection per point with automatic de-energization
  • On-State Voltage Drop: ≤ 0.5 V at 2 A
  • Off-State Leakage Current: ≤ 1 mA
  • Switching Frequency: Max 20 Hz sustained
  • Response Time: ≤ 10 ms (command to output) + ≤ 10 ms fault detection
  • Galvanic Isolation: 1500 V RMS channel-to-backplane and channel-to-channel
  • Power Consumption: 12 W typical, 18 W maximum
  • Operating Temperature: –20 °C to +70 °C (extended range with derating)
  • Vibration: 2 g @ 10–500 Hz per IEC 61131-2
  • Certifications: TÜV Rheinland SIL 3 (IEC 61508), AK6, Nuclear 1E qualified (IEEE 323, 344), ATEX Zone 2 / Class I Div 2
  • MTBF: > 1,200,000 hours (demonstrated per MIL-HDBK-217F at 40 °C)
Category: SKU: HD-8311 TRICONEX
  • Email:sales@sxrunsheng.cn
  • Phone:+86 15340667322
  • Whatsapp:+86 15340667322
  • Description

    Technical Architecture & Functional Positioning

    The HD-8311 resides at the field termination layer of the Triconex TMR (Triple Modular Redundant) architecture. Each of the 32 output points is controlled by three independent legs (A, B, C) running in parallel on separate I/O processors. Voter circuits in the main chassis continuously compare the three legs and drive the final output only when at least two legs agree (2oo3 voting), ensuring that a single fault cannot cause an erroneous actuation or loss of control.

    The module incorporates active line-monitoring circuitry that injects a low-level wetting current during the OFF state to detect open circuits and, during the ON state, monitors voltage drop to detect short circuits or overloads. Upon detecting a discrepancy, the affected point is automatically de-energized and a diagnostic fault is reported to the TriStation 1131 software within 20 ms. This supervised output capability is mandatory for SIL 3 emergency shutdown valves, burner management, and fire & gas suppression systems.

    Engineering value lies in eliminating external monitoring relays and reducing field wiring complexity. A single HD-8311 replaces up to 32 conventional relay outputs plus associated interposing monitoring circuits, dramatically lowering cabinet space, power consumption, and spare parts inventory while increasing diagnostic coverage to >99%.

    Typical Application Scenarios

    • Emergency shutdown (ESD) systems in refineries and offshore platforms driving on/off valves and motor starters
    • Burner management systems (BMS) controlling fuel shut-off valves in power plants and furnaces
    • Fire & gas systems actuating deluge valves, suppression agents, and HVAC dampers
    • Turbine trip circuits in nuclear and fossil power generation
    • High-integrity pressure protection systems (HIPPS) in subsea and pipeline applications
    • Critical process interlocks requiring TÜV-certified SIL 3 capability with full diagnostics

     

    Quality Standards & Testing Procedures

    A failed safety output module can initiate a spurious trip costing millions or, worse, fail to trip during a demand. We treat every HD-8311 as if an entire plant’s safety depends on it—because it often does.

    Every unit follows a documented 32-step SOP performed on a live Tricon v11 chassis with TriStation 1131 v4.11 or higher.

    Standardized Testing Protocol (SOP)

    Visual Inspection & Cleaning 100× magnification inspection of all solder joints, capacitors, optocouplers, and TMR leg segregation barriers. Ultrasonic cleaning followed by ionized air blow-off.

    Live Burn-In Minimum 48-hour continuous operation at 60 °C ambient on a fully loaded 15-slot chassis with all three legs active and 100% duty cycle toggling.

    Functional Verification

    • 100% channel exercising: each of the 32 points cycled >10,000 times at 2 A resistive + inductive load (L/R = 40 ms)
    • Line-monitoring validation: open-circuit, short-to-ground, and short-to-24V injected on every point with correct fault reporting within 20 ms
    • 2oo3 voting verification: single-leg faults forced via diagnostic port with no change in output state
    • Hot-insert/removal test performed six times while system is online and under load
    • Full TriStation diagnostics capture confirming zero latent faults

    Firmware & Revision Control EEPROM contents verified against Schneider Electric reference checksums for Rev E/F. Revision letter physically confirmed on PCB silkscreen.

    Final QC & Documentation Only units with zero faults across all tests are released. Each module ships with a signed 8-page test report including oscilloscope captures of switching transients, fault response times, and TriStation diagnostic screenshots.

    HD-8311 TRICONEX

    Pack Driver AK-BX910M DIT5 Stepping Motor Driver

    Pacific Scientific 5240 Indexer Drive 115VAC

    SPECIAL OPTICS 56-30-2-8X LASER BEAM EXPANDER

    GE Fanuc Horner Electric HE693STP111E Stepper Motor

    ARCOM CONTROL PCAD12/16H 16-CH 12-BIT ADC BOARD

    QUANTRONIX SHUTTER Assembly 319 0103-00483 REV G NEW

    Beckhoff FC2002 FC 2002 LIGHTBUS Interface 2 channels

    PRO-FACE GP37W2-BG41-24V QPM3D200B2P TOUCHSCREEN PANEL

    TEKTRONIX 012-1661-00 LOGIC ANALYZER INTERFACES CABLE

    PARKER ZETA6108 ZETA 6108 SERVO DRIVE INDEXER

    MERLIN GERIN PM500 PM 500 POWER LOGIC SYSTEM

    Yaskawa AC Servo SGDL-01AS & SGML-​01AF 12 100W