Sale!

ProSoft MVI94-MCM-MHI | Genuine Industrial Modbus Serial Module

Original price was: $6,576.00.Current price is: $2,432.00.

  • Model: MVI94-MCM-MHI
  • Brand: ProSoft Technology
  • Series: MVI94 FLEX I/O Communication Modules
  • Core Function: Exchanges Modbus serial data between FLEX I/O PLC and field devices
  • Type: Communication Module / Serial Gateway
  • Key Specs: Modbus RTU/ASCII master & slave; dual serial ports (RS-232/422/485); up to 5,000 registers
  • Condition: New Original (New Surplus) — not refurbished
Category: SKU: MVI94-MCM-MHI PROSOFT
  • Email:sales@sxrunsheng.cn
  • Phone:+86 15340667322
  • Whatsapp:+86 15340667322
  • Description

    ProSoft MVI94-MCM-MHI is a Modbus master/slave communication module designed for Allen-Bradley 1794 FLEX I/O systems, enabling serial data exchange between PLC backplanes and Modbus-compatible field devices such as meters, drives, and remote I/O. It installs as a single-slot module and operates via ladder logic mapping.

    Configured with dual serial ports and support for up to 5,000 registers, it handles both polling and slave responses in the same module. In real projects, this reduces the need for external gateways and keeps protocol handling inside the rack — less wiring, fewer failure points (though configuration still takes care).

     

    Installation & Configuration Guide

    Phase 1 — Pre-Installation (est. 10 min)
    De-energize rack. Wait 5 minutes. Tools: laptop (RSLogix + ProSoft Config Builder), serial cable, labels, multimeter. Back up PLC logic and Modbus mapping. Photograph wiring and terminal base.

    Phase 2 — Removal (est. 5 min)
    Label all serial lines (TX/RX or A/B). Remove module from FLEX terminal base. Inspect backplane connector — small damage here causes intermittent faults later.

    Phase 3 — Installation (est. 10 min)
    ESD first. Confirm module and terminal base compatibility. Insert module into 1794 base. Wire serial ports (set RS-232 or RS-485 via jumper). Configure baud rate, parity, node addressing, and command list in ProSoft Config Builder.

    Phase 4 — Power-On & Testing (est. 15 min)
    Apply power (12–24 V DC external + backplane). Check LED indicators. Validate Modbus communication using test device. Execute read/write commands (FC03, FC06, FC16). Run stable polling for >30 min and confirm no CRC or timeout errors.

    Troubleshooting quick-reference:
    • No comms → check baud rate, parity, wiring polarity
    • CRC errors → inspect shielding and noise sources
    • No data in PLC → verify register mapping and command list

    ProSoft MVI94-MCM-MHI | Genuine Industrial Modbus Serial Module

    Edwards iQDP80 Vacuum Pump QMB250 Blower Rebuilt

    EDWARDS QDP80 DRY SEMICONDUCTOR DRYSTAR VACUUM PUMP+CTL

    Leybold Turbovac 1000 C Vacuum Turbopump rebuilt

    Toyota T600 Vacuum Dry Pump 0240-52730 new

    Toyota T600 Vacuum Dry Pump new 0240-52729

    CL1002 NASH VACUUM PUMP, 60 HP

    Used: Nash vacuum pump, type CL1003. Approximately 330

    Used: Nash vacuum pump, type CL1003, Approximately 330

    Used: Nash vacuum pump, type CL1003, Approximately 330

    EDWARDS QDP80 DRY SEMICONDUCTOR DRYSTAR VACUUM PUMP+CL

    Super Vac Vacuum Sealer (does not include pump)

    Busch Cobra DS-80 Dry Pump – Used

    3 GS Kinney KT-150 Vacuum Pump Rotary Piston

    NuCond-Edwards iQDP80/QMB500 Vacuum Dry Pump-iQDP 80-NR

    SET OF CONTROLLER+POMP​E TURBO+CABLES – REFURBISHED

    Leybold TW 700 Vacuum Turbo Pump: Factory Rebuild
    Rebuilt by Leybold with a one year warranty.
    One-day shipping available

    CTI 8120992G001 Series 14 On-Board Water Pump Vacuum