  • Model: MVI56E-MNETC
  • Brand: ProSoft Technology
  • Series: MVI56E Enhanced Communication Modules
  • Core Function: Bridges ControlLogix PLCs with Modbus TCP/IP networks
  • Type: Communication Module (Modbus TCP Client/Server)
  • Key Specs: 30 client / 40 server connections; 10/100 Mbps Ethernet; 10,000 registers mapping
  • Condition: New Original (New Surplus) — not refurbished
Category: SKU: MVI56E-MNETC PROSOFT
  • Email:sales@sxrunsheng.cn
  • Phone:+86 15340667322
  • Whatsapp:+86 15340667322
  • Description

    ProSoft MVI56E-MNETC is a Modbus TCP/IP communication module designed for Rockwell ControlLogix systems, enabling PLCs to exchange data with Modbus-based SCADA, drives, analyzers, and remote I/O devices over Ethernet networks.

    Built on the enhanced MVI56E platform, it supports multi-client and multi-server communication simultaneously (up to 30 client and 40 server connections) with configurable memory mapping up to 10,000 16-bit registers. Typical procurement lead time ranges from stock availability (1–10 days) to 4–6 weeks for configured supply depending on market conditions.

     

    Phase 1 — Pre-Installation (est. 10 min)

    Power down rack; wait 5 minutes.
    Tools: screwdriver, laptop with ProSoft Configuration Builder, ESD strap, Fluke 115 multimeter.
    Export PLC project. Back up existing Modbus mapping. Photograph slot and wiring.

     

    Phase 2 — Removal (est. 5 min)

    Label Ethernet and backplane references.
    Pull module straight out — no twisting.
    Inspect backplane pins carefully. Bent pins are a real issue.

     

    Phase 3 — Installation (est. 10 min)

    ESD protection first.
    Confirm MVI56E-MNETC model.
    Insert into slot; latch fully.
    Connect Ethernet (shielded CAT5e/6).
    Load configuration via PCB software.

     

    Phase 4 — Power-On & Testing (est. 15 min)

    Apply power.
    Check LED display for IP and status.
    Ping module IP.
    Test Modbus read/write with SCADA or simulator.
    Verify at least one full data cycle and stable comms >30 min.

    Troubleshooting quick-reference

    • No Ethernet → check IP/subnet and switch port
    • No Modbus data → verify register mapping and function codes
    • ERR LED → firmware/config mismatch

    ProSoft MVI56E-MNETC | Multi-Client Server Interface In Stock

    Enlarge
    Rotary Vane Oil Vacuum Pump with Motor MVP-432 NIB

    Oil Rotary Piston Vacuum Pump WSSR 7.5K

    Roots Vacuum Pump FRU1440 NIB

    EC150L NASH VACUUM PUMP SYSTEM

    EIM275 EDWARDS VACUUM PUMP, 8.5 KW

    EIM275 EDWARDS VACUUM PUMP, 8.5 KW

    EIM275 EDWARDS VACUUM PUMP, 8.5 KW

    EIM275 EDWARDS VACUUM PUMP, 8.5 KW

    10 HP rotary vane vacuum pump by Busch

    USED:Kinney liquid ring vacuum pump, model 125-KSS, ski

    Perkin-Elmer Ion Pump Vacuum Chamber Bell Jar System

    Leybold/Oerliko​n TMP 1100C turbo pump ” REFURBISHED ”

    LAMSON 100HP BLOWER

    Holmes HV1000 Blower Vacuum Pump 700.0 CFM

    Holmes HV1250 Blower Vacuum Pump 875.0 CFM

    OSAKA VACUUM HELICALGROOVED PUMP, Model TS443BW