Product Core Brief
- Model: IS2020RKPSG2A
- Brand: GE (General Electric)
- Series: Mark VIe Control System
- Core Function: Direct-current power conversion, regulation, and system bus voltage distribution
- Type: Rack Power Supply Module (RKPS)
- Key Specs: 24 VDC output distribution, dual AC/DC bulk power input interfaces, status diagnostic output contacts
- Condition: New Original (New Surplus), not refurbished
Product Introduction
How often do transient DC bus dips or floating ground faults cause unexpected I/O pack dropouts across your Mark VIe cabinet? The GE IS2020RKPSG2A is a dedicated rack power supply module engineered specifically to provide clean, regulated 24 VDC power to GE Mark VIe controller racks and backplane buses.
Control room technicians depend on the GE IS2020RKPSG2A to maintain uninterrupted DC power distribution across critical turbine protection networks. Operating within high-density control panels, the module filters raw station power while suppressing line spikes from adjacent high-voltage switching equipment.
Key Selling Points & Differentiators
- Direct slot compatibility for Mark VIe controller chassis without requiring harness modifications.
- Fully bench-tested under 100% full-load step conditions; complete ripple voltage and thermal stability logs generated prior to shipment.
- Features fast-acting output overvoltage and short-circuit protection to prevent power fault propagation to downstream I/O packs.
- Not recommended for high-power field solenoid coil actuation outside designed Mark VIe backplane power boundaries.
- Manufactured in full compliance with IEEE 1613 and IEC 61000-6-2 surge withstand standards for power plant environments.
Quality Transparency SOP
- Incoming Inspection: Serial number check against GE manufacturing databases; visual verification of module housing, connector pins, front diagnostic LEDs, and circuit board traces.
- Live Functional Test: Mounted on a Mark VIe test rack chassis. Verified DC power-up sequencing, output rail stability across zero to 100% load steps, status LED indication, and health contact closure. Held under continuous full-load run for 24 hours while logging internal heat rise.
- Electrical Parameter Tests: Insulation resistance checked with a 500 VDC Megger (>10 MΩ target) across power supply inputs and chassis earth ground.
- Firmware / Hardware Version Verification: Documented hardware revision suffix (G2A), internal jumper settings, and component date codes against OEM specifications.
- Final QC + Packaging: QC sign-off completed, module sealed inside an anti-static ESD shielding bag, padded with heavy protective foam, and boxed in a reinforced carton with a dated QC Pass sticker.