Sale!

ABB REF615C-C | REF615C Series 3-Phase Overcurrent Relay, OEM

Original price was: $7,867.00.Current price is: $4,353.00.

Product Core Brief

  • Model: REF615C-C HCFFAEAGANB2BNN1XC
  • Brand: ABB
  • Series: REF615C
  • Core Function: Monitors and protects 3-phase feeders
  • Type: Protection Relay
  • Key Specs: Rated voltage 110–250 V AC/DC, I/O points 8 DI / 4 DO, Communication IEC 61850/Modbus
  • Condition: New Original (New Surplus)
  • Availability: In Stock
Category: SKU: REF615C-C HCFFAEAGANB2BNN1XC ABB
  • Email:sales@sxrunsheng.cn
  • Phone:+86 15340667322
  • Whatsapp:+86 15340667322
  • Description

    Product Introduction

    Data first — the ABB REF615C-C HCFFAEAGANB2BNN1XC is a feeder protection relay designed for medium-voltage systems in substations, industrial plants, and critical infrastructure. This unit monitors current, voltage, and frequency, providing overcurrent, earth-fault, and breaker failure protection.

    Engineers will appreciate that the REF615C-C can process analog and digital signals in <2 ms. Communication includes IEC 61850 MMS, DNP3, and Modbus RTU/TCP, making integration into SCADA or automation networks straightforward. Lead time is typically 2–3 weeks from verified stock, and full test reports are available upon reques

    ABB REF615C-C | REF615C Series 3-Phase Overcurrent Relay, OEM ABB REF615C-C | REF615C Series 3-Phase Overcurrent Relay, OEM

     

    Installation & Configuration Guide

    Phase 1 — Pre-Installation (est. 10 min)

    • De-energize panel; wait 5 min for capacitors to discharge
    • Tools: Fluke 115 multimeter, screwdriver, torque wrench
    • Backup: Export relay program; photograph DIP switches, jumper settings, wiring, and rack layout

    Phase 2 — Removal (est. 5 min)

    • Label wires before disconnecting
    • Release DIN rail latch; pull module perpendicular to backplane
    • Inspect backplane connector pins for corrosion or misalignment

    Phase 3 — Installation (est. 10 min)

    • Wear wrist strap; verify ESD mat
    • Confirm ABB REF615C-C part number
    • Replicate DIP switch/jumper settings from photos
    • Seat module until latch clicks; reconnect wiring at ~0.5 N·m
    • Run pre-power checklist

    Phase 4 — Power-On & Testing (est. 15 min)

    • Verify 24 V DC ±10% supply
    • Observe LEDs: green = RUN / red = ERR / amber = DIAG
    • Connect programming software; download program
    • Functional test: verify all I/O points and one full control loop
    • Confirm >30 min stable operation; log swap in maintenance record

    Troubleshooting Quick Reference

    • No comms → check IP, cable, switch port
    • ERR steady → firmware mismatch; attempt update
    • Download fails → confirm software version and cable type

    t.