Product Core Brief

  • Model: FSM 006A64
  • Brand: SAACKE GmbH
  • Series: SAFERON / Burner Safety Series
  • Core Function: Continuously supervises burner flame presence via ultraviolet (UV) radiation sensing and provides immediate trip signals to Burner Management Systems (BMS) upon flame failure.
  • Type: High-Sensitivity UV Flame Scanner Module
  • Key Specs: 180–260 nm (UV-C) spectral range, <200 ms trip response time, 24 V DC power supply, dry contact relay output (5 A @ 250 V AC)
  • Condition: New Original (New Surplus) — not refurbished
Category: SKU: FSM 006A64 SAACKE
  • Email:sales@sxrunsheng.cn
  • Phone:+86 15340667322
  • Whatsapp:+86 15340667322
  • Description

    Product Introduction

    The SAACKE FSM 006A64 flame scanner continuously monitors combustion stability across oil-, gas-, and dual-fuel-fired marine boilers and industrial furnaces. Mounted directly onto the burner sight tube or wall flange, it detects the presence or absence of primary hydrocarbon combustion. Bottom line — it works.

    Utilizing a solar-blind ultraviolet detector tube sensitive strictly to the 180–260 nm spectrum, the module ignores refractory glow, infrared radiation, and ambient background lighting. Operating with a response time under 200 ms, it immediately signals the BMS to isolate fuel shut-off valves in the event of flameout. Honestly, integrating self-checking UV diagnostics directly into an IP66 enclosure is actually clever for preventing unburned fuel accumulation in high-vibration marine engine rooms.

    SAACKE FSM 006A64 | Fail-Safe Flame Monitor 1-Year Warranty

    Pricing & Availability Note: Listed pricing is for baseline reference only; actual unit cost varies depending on supply chain availability and delivery speed. Request a formal quotation to confirm current stock and lead time for the SAACKE FSM 006A64.

     

    Installation & Configuration Guide

    Phase 1 — Pre-Installation (est. 10 min)

    1. Lock out and tag out the main burner power panel and close manual fuel isolation valves.
    2. Wait 5 minutes for boiler furnace draft fans to purge residual gases and cool the sight tube.
    3. Bring a 36 mm wrench, an ESD wrist strap, optical lens cleaner, and a Fluke 115 multimeter.
    4. Photograph existing sight tube angle alignment and wiring connections at the terminal junction box.

    Phase 2 — Removal (est. 5 min)

    1. Disconnect the quick-disconnect cable or field wiring terminals from the rear housing.
    2. If fitted, disconnect instrument air purge lines from the cooling sleeve port.
    3. Unthread the retaining collar holding the module onto the M42 x 1.5 sight tube flange.
    4. Pull the scanner straight back off the sight tube and inspect the optical quartz lens.

    Phase 3 — Installation (est. 10 min)

    1. Put on a grounded ESD wrist strap before handling internal wiring connections.
    2. Inspect the scanner side label to confirm the model reads SAACKE FSM 006A64.
    3. Align the quartz viewing window with the burner flame root zone (avoiding direct sight lines to opposite furnace walls).
    4. Screw the scanner housing onto the M42 flange adapter hand-tight, then torque to 15 N·m using a wrench.
    5. Connect oil-free instrument purge air (3 to 5 bar) to the cooling port if ambient temperature exceeds 70 °C.

    Phase 4 — Power-On & Testing (est. 15 min)

    1. Apply 24 V DC power to the scanner terminals.
    2. Observe front-panel status indicators (green LED indicates power OK; yellow LED indicates flame presence).
    3. Initiate the burner start sequence and verify the output relay closes within 1 second of main flame ignition.
    4. Perform a simulated flame failure test by blocking the sight glass; confirm relay drops out in under 200 ms.
    5. Monitor background signal voltage for 30 minutes to confirm no false triggers from furnace refractory glow.

    Quality Verification SOP

    In marine and industrial boiler operations, strict flame scanner verification prevents boiler explosions and unannounced shutdowns. Every SAACKE FSM 006A64 module undergoes systematic physical and operational checks prior to dispatch:

    • Incoming Inspection: We examine OEM tags, housing seals, and factory documentation. Optical components are inspected under magnification for scratches, coating flaws, or seal degradation.
    • Live Functional Test: Mounting the unit on a burner test rig, we simulate oil/gas flames and background IR noise. We verify spectral selectivity (180–260 nm), measure trip response time (<200 ms), and execute a 24-hour continuous thermal stability burn-in. A formal Test Report accompanies each unit.
    • Electrical Tests: Insulation resistance between terminal connections and outer chassis frame is checked with a 500 V megohmmeter (confirming >10 MΩ). Ground continuity across the housing and conduit entry is verified using a Fluke 115 multimeter.
    • Optical & Diagnostic Check: Built-in test functions and optical shutter self-tests are triggered repeatedly to verify diagnostic relay output reliability.
    • Final QC & Packaging: Following engineer approval, the unit is wrapped in static shielding material, cushioned in shock-absorbing foam inside a reinforced box, and sealed with a dated QC Passed badge.